Difference between revisions of "V2/Integrate/Others/MQTT"

From Senfi Docs
Jump to: navigation, search
m (A missing "]" is added to the "Single measurement" example.)
 
(3 intermediate revisions by 3 users not shown)
Line 8: Line 8:
 
A typical integration follows this pattern:
 
A typical integration follows this pattern:
  
  External system --> Your application --> Senfi MQTT endpoint
+
  External system → Your application → Senfi MQTT endpoint
  
 
Either the external system you are monitoring pushes to your application, or your application polls the external system for its current values. Either way, once your application has the values of its measurement, you can prepare to send it to Senfi's MQTT endpoint.
 
Either the external system you are monitoring pushes to your application, or your application polls the external system for its current values. Either way, once your application has the values of its measurement, you can prepare to send it to Senfi's MQTT endpoint.
Line 27: Line 27:
 
       {
 
       {
 
         "tm_source": xxxxxxxxxx,
 
         "tm_source": xxxxxxxxxx,
        "site_id" xxxxxxxx,
 
 
         "tag1": "xxxxxxxx",
 
         "tag1": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
Line 34: Line 33:
 
         ...
 
         ...
 
       }
 
       }
 +
    ]
 
   }
 
   }
  
Line 41: Line 41:
 
       {
 
       {
 
         "tm_source": xxxxxxxxxx,
 
         "tm_source": xxxxxxxxxx,
        "site_id" xxxxxxxx,
 
 
         "tag1": "xxxxxxxx",
 
         "tag1": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
Line 49: Line 48:
 
       },
 
       },
 
       {
 
       {
         "tm_source": xxxxxxxxxx,
+
         "tm_source": xxxxxxxxxx
        "site_id" xxxxxxxx,
 
 
         "tag1": "xxxxxxxx",
 
         "tag1": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
 
         "tag2": "xxxxxxxx",
Line 60: Line 58:
 
   }
 
   }
  
You must indicate which [[V2/Concepts/Site|Site]] the measurement is meant for. Hence, you need to include the site ID (site_id) in your MQTT message. If your measurement has other tags, you must send them in the message as well.
+
You must send Tags of the measurement in the message.
  
 
<div class="important">Note: '''All''' tags and metrics must be sent in your message body, or they will be treated as invalid data and discarded.</div>
 
<div class="important">Note: '''All''' tags and metrics must be sent in your message body, or they will be treated as invalid data and discarded.</div>

Latest revision as of 08:46, 31 March 2022

Publish to MQTT

To start sending data to Senfi, you need to do the following:

  1. Create an integration key/secret pair in the CMS.
  2. Design and create a measurement in the CMS.
  3. Write a program to read from your system and send it to Senfi's MQTT Endpoint.

A typical integration follows this pattern:

External system → Your application → Senfi MQTT endpoint

Either the external system you are monitoring pushes to your application, or your application polls the external system for its current values. Either way, once your application has the values of its measurement, you can prepare to send it to Senfi's MQTT endpoint.

MQTT Endpoint

Host
mqtt.senfi.io
Port
1883
Username
<Your integration key>
Password
<Your integration secret>
MQTT topic
ingestor/2/0/live/text/array/<your integration key>/<your measurement code>

Message Format

The message body should be in valid JSON format.

Single measurement

 {
   "data": [
     {
       "tm_source": xxxxxxxxxx,
       "tag1": "xxxxxxxx",
       "tag2": "xxxxxxxx",
       "metric1": xxxxxxxxx,
       "metric2": xxxxxxxxx
       ...
     }
    ]
 }

Multiple measurements

 {
   "data": [
     {
       "tm_source": xxxxxxxxxx,
       "tag1": "xxxxxxxx",
       "tag2": "xxxxxxxx",
       "metric1": xxxxxxxxx,
       "metric2": xxxxxxxxx
       ...
     },
     {
       "tm_source": xxxxxxxxxx
       "tag1": "xxxxxxxx",
       "tag2": "xxxxxxxx",
       "metric1": xxxxxxxxx,
       "metric2": xxxxxxxxx,
       ...
     }
   ]
 }

You must send Tags of the measurement in the message.

Note: All tags and metrics must be sent in your message body, or they will be treated as invalid data and discarded.

Sample Application

You can take a look at this GitHub repository for a sample application to send data to Senfi's MQTT endpoint.